+27 21 852 4719 [email protected] Mon-Fri 8:00-17:30 (SAST)
Custom Wire Harness Manufacturing

Custom Wire Harness Manufacturing

Browse technical resources about OM5/OS2 fiber, FC/ST connectors, distribution boxes, circulators, QSFP28, PDU, FTTR, rail transit and communication cabling.

  • Correct way to connect copper wire cold joints

    Correct way to connect copper wire cold joints

    Clean and prep the joint, dry-fit with a slight capillary gap, and flow low-rate nitrogen through the tubing. Allow to air-cool, wipe residue, then pressure- and. There are several categories of methods to join copper tube and fittings: These joining methods include soldering, brazing and electric resistance. Brazed joints, with capillary fittings, are. Soldering copper creates strong, clean joints that are perfect for water lines, decorative pieces, or electronics. When I first started, I made a mess—blobby joints, leaks, and burnt copper. But after plenty of practice and a few mistakes, I've nailed down a process that works every time. I'm. This technical article explains how to solder wires effectively, covering tools, techniques, tinning, flux selection, solder joints, and modern automation trends for achieving reliable, high-performance electrical connections in engineering applications. This guide focuses on heat balance, joint prep, nitrogen purging, and filler techniques that consistently produce clean, leak-free joints in real-world installs.

    [PDF Version]
  • Fiber optic cable overhead ground wire

    Fiber optic cable overhead ground wire

    An optical ground wire (also known as an OPGW or, in the IEEE standard, an optical fiber composite overhead ground wire) is a type of cable that is used in overhead power lines. Such cable combines the functions of grounding and telecommunications. Application OPGW is mainly applied in communication line of newly constructed high voltage transmit electricity system with 35 KV or above, or replacement of existing ground wire of previous overhead high voltage transmit electricity system. OPGW is primarily used by the electric utility industry, placed in the secure topmost position of the transmission line where it “shields” the all-important conductors from lightning while providing a telecommunications path for internal as well as third party communications. Installed at the top of high-voltage and extra-high-voltage transmission lines, OPGW cables provide lightning.

    [PDF Version]
  • Standard for lightning protection grounding wire of distribution box

    Standard for lightning protection grounding wire of distribution box

    The UL Standard 96 addresses the minimum requirements for construction of air terminals, cable conductors, fittings, connectors, and fasteners used in quality lightning protection systems. This manual is provided for the use of all Departments of the ITER Organization and is addressed to system specifiers, designers and users of electrical components in otherwise non-electrical plant systems. For almost 100 years, OBO has been devel-oping and producing standard-compliant lightning pro-tection components. The lightning protection industry began in the United States when Benjamin Franklin postulated that lightning was electricity, and a metal. IBILITY: Publications and forms are available for downloading or ordering o rements for electrical grounding systems, including systems for equipment grounding, lightning protection, and static protection. While the NFPA administers the process and establishes rules to promote fairness in the. Today, we're diving deep into the world of distribution box grounding, breaking down the standards, and shining a light on those sneaky mistakes that even experienced electricians sometimes make.

    [PDF Version]
  • Are fiber optic patch cords always connected by a separate wire

    Are fiber optic patch cords always connected by a separate wire

    Standard fiber patch cords have the same connector type on both ends, such as LC to LC fiber patch cord and SC to SC fiber patch cord. A fiber optic patch cord (fiber jumper) is: Typical applications: A patch cord is the “bridge” that connects two fiber devices and lets them talk to each other. ZION Communication supplies both standard patch cords and custom assemblies to match your equipment, distance, and installation. When you build or upgrade a fiber network, the same four words pop up everywhere— fiber optic (bare fiber), pigtail, patch cord, optical cable. They're related, but they are not interchangeable. Mixing them up drives costs higher, increases loss, and slows your rollout. Understanding the various technical. Whether back in the late 1990s or today, you will see 8P8C RJ45 type connectors at the end of Ethernet patch cords and keystone jacks mounted in walls running back to patch panels. They are generally sold in large quantities, rather than custom -made, although quite special models are also.

    [PDF Version]
  • Distribution Box Wire Breaker

    Distribution Box Wire Breaker

    Circuit breaker wiring configurations involve organizing main switches, busbars, and branch breakers within a distribution box. Proper setups ensure balanced electrical loads, ground fault protection, and easy maintenance. Electrical systems power our homes, offices, and industrial facilities, but behind every reliable electrical setup lies a crucial component that often goes unnoticed: the distribution box. This essential piece of equipment serves as the nerve center of your electrical system, managing power flow. A distribution box, or DB box, is a circuit breaker enclosure. The hub distributes electrical power from a single input source to various circuits throughout a building. Comply with standards: Follow NEC, IEC, or local codes.


  • How to find the neutral and live wire circuit in a distribution box

    How to find the neutral and live wire circuit in a distribution box

    To identify neutral and live wires safely, you should first turn off the power to the circuit at the main electrical panel or breaker box. Verify that the power is off using a non-contact voltage tester. First, select the appropriate AC voltage range (higher than the supply voltage in your area) on your multimeter. Then use the hit-and-trial method to check the. In this video, you'll learn how to identify the live (phase) and neutral wires using a digital multimeter — without any special tools! Set your multimeter to AC voltage mode, leave the black probe free, and test both wires usin. Single Phase Distribution Box generally consists of Double Pole MCBs, Single Pole MCBs, and RCCBs. It includes isolator, RCCB (Residual current circuit breaker) or RCD (Residual-current device) devices, protective fuses or MCB's (Miniature Circuit Breaker).


  • How to make the wire mesh cable tray look neat when offline

    How to make the wire mesh cable tray look neat when offline

    Consider a cable management box to hide unsightly wires. Utilize binder clips on your desk for easy access. Don't forget about desk grommets. This article shares simple ways to plan your cable trays and wiring. We want to help electrical engineers, technicians, and anyone working with electrical setups build safe and good systems. These can be easily wrapped around a group of cables to keep them neat and prevent tangling. Once you've got that, you may consider routing it along the frame of the desk, or cable rails as was mentioned in another. Benefits for the NETWORK (and users!): Much more than just a neat and professional appearance, better cable management offers a safe and easy way to maintain and service a network.


  • Secondary protective grounding wire connection method for distribution box

    Secondary protective grounding wire connection method for distribution box

    Attach a ground wire from one of the threaded studs (A) at the bottom of the housing, to the mounting plate (B). The ground resistance between all system parts shall be <. This technical article covers protective grounding requirements for steel tower and wood pole supported transmission and distribution lines, and insulated power cables. Protective grounds must be installed so all phases of lines or cable are visibly and effectively bonded together in a multi-phase. Grounding is a mechanism to protect distribution equipment and people under normal operating conditions, abnormal operational (overcurrent and overvoltage) responses, and hazardous conditions such as shocks. Grounding is necessary to assure correct operation of electrical devices, to assure safety. There are several factors that make substation grounding absolutely necessary. Safety of Personnel: By safely channeling fault currents into the ground, proper grounding helps to reduce the risk of electric shock to personnel. Depending upon the. This manual is applicable for low voltage AC and DC drive systems.

    [PDF Version]

Need Product Pricing?

Contact us for competitive quotes on any of our fiber optic and telecom products

Get a Quote