+27 21 852 4719 [email protected] Mon-Fri 8:00-17:30 (SAST)
How Optocouplers Work

How Optocouplers Work

Browse technical resources about OM5/OS2 fiber, FC/ST connectors, distribution boxes, circulators, QSFP28, PDU, FTTR, rail transit and communication cabling.

  • How to shut down a PoE switch

    How to shut down a PoE switch

    Use a Network Scanner ( for example Fing) to determine the IP address of the Cisco Switch 3. Select all Port. When you use "shut" you are turning off the port transmit/receive and PoE. To disable PoE only for an interface, go into interface config mode and use "power inline never" and then to enable PoE use "power inline auto" 07-18-2023 01:05 AM I would like to reactivate the topic. Login in the Cisco Switch ( using credentials provided by customer support) 5. The no form of the command disables PoE operation on <port-list>. If you configure a higher. It is good practise when installing AES67 networks to turn off the PoE (Power over Ethernet) functionality on any Ethernet-switch port that does not require it Clear-Com recommends you disable PoE on switch ports connected to to avoid rare unexpected brief down/up events which affect the. Use these commands to administratively shut down or bring up a switch port. Shorthand: Interface names can be abbreviated — gi1/0/5 instead of GigabitEthernet1/0/5, or fa0/5 for FastEthernet.

    [PDF Version]
  • How to calculate the price of pigtail fabrication

    How to calculate the price of pigtail fabrication

    The basic formula is as follows: Total Cost = (Weight of Steel × Cost per Unit Weight) + (Overhead Percentage × Material Cost)The basic formula is as follows: Total Cost = (Weight of Steel × Cost per Unit Weight) + (Overhead Percentage × Material Cost)Steel and metal prices change daily, so a steel and metal price calculator helps you instantly estimate the cost per pound, per kg, per ton, or per CWT for any material—including steel, aluminum, cast iron, nickel alloys, bronze, and Hastelloy. This tool quickly answers how much metal costs. Fabrication cost estimation is a critical process in manufacturing, providing businesses with a clear understanding of the expenses involved in creating parts, products, and structures. To use the Steel Fabrication Cost Estimator effectively, follow these simple steps. Select from various metal types (steel, stainless steel, aluminum, brass), choose different shapes, and enter custom dimensions to plan your project budget.

    [PDF Version]
  • How to configure interconnection between core switches

    How to configure interconnection between core switches

    To establish a VSX relationship between the core switches, create a link aggregation (LAG) interface for assignment as the VSX data plane's inter-switch link (ISL). The LAG can be defined at the Central UI group level when using the same ports for the VSX ISL on both core. Therefore, you are advised to configure corresponding VPN instances on the core switch to isolate traffic and send the traffic to the corresponding ISPs. It is a 12-bit identity used to create multiple broadcast domains in a switch. VLAN ranges from 0 to 4095 (VLAN 0 and VLAN 4095 are reserved and not used). This Switch Port mode is configured by the admin. The slot is used to install various function modules and interface modules.


  • How to wire a DCS cabinet

    How to wire a DCS cabinet

    This guide summarizes field-proven rules for AI/AO/DI/DO wiring, shows how to choose between NO/NC contacts under the fail-safe principle, and explains how to decode typical cable schedule entries. PLC and DCS control systems Wiring Diagrams for Digital Input (DI), Digital Output (DO), Analog Input (AI), and Analog Output (AO) signals. There are four types of inputs and outputs in PLC and DCS systems. Digital Input Pressure switches, level switches, temperature switches, flow switches, vibration switches, on-off feedback of valves, run indications of any. Welcome to the Principle Cabinet Design training module for the DCS800, ABB DC drives. If you need help navigating this module, please click the Help button in the top right-hand corner.


  • How to find the neutral and live wire circuit in a distribution box

    How to find the neutral and live wire circuit in a distribution box

    To identify neutral and live wires safely, you should first turn off the power to the circuit at the main electrical panel or breaker box. Verify that the power is off using a non-contact voltage tester. First, select the appropriate AC voltage range (higher than the supply voltage in your area) on your multimeter. Then use the hit-and-trial method to check the. In this video, you'll learn how to identify the live (phase) and neutral wires using a digital multimeter — without any special tools! Set your multimeter to AC voltage mode, leave the black probe free, and test both wires usin. Single Phase Distribution Box generally consists of Double Pole MCBs, Single Pole MCBs, and RCCBs. It includes isolator, RCCB (Residual current circuit breaker) or RCD (Residual-current device) devices, protective fuses or MCB's (Miniature Circuit Breaker).


  • How much does a 96-core Panama ADSS fiber optic cable cost

    How much does a 96-core Panama ADSS fiber optic cable cost

    Discover our 96 core ADSS fiber optic cable, available in bulk from $0. Suitable for orders of 1,000 units or more for telecommunications and high-speed data transmission., Singlemode, Single Jacket, Loose Tube, SMF28e, Dry/Dry, 500′ Max Span NESC Medium Load, Price Per Ft. American Tech Supply Can Deliver ADSS Fiber Cable, Ribbon Cable, all armored, Gel and Gel Free singlemode fiber cable from 6 fibers to 144 fibers to 432 fiber up to 864 fibers which is Telecordia approved and meets all GR 20 Requirements for Optical Fiber and Optical Fiber Cable. As a distributor. There's a trend towards higher fiber counts (48, 96, 144-core) within standard ADSS designs. Suppliers offer aggressive bulk discounts, with prices dropping 30-60% for large orders. It has highly appraised by it's customers with superior quality, perfect service and advanced technology (with 12 high speed producing lines, available to manufacture 216. 36-Core ADSS (Aerial Drop Self-Supporting) Fiber Optic Cable designed for aerial installations in telecom and data networks, including FTTH (Fiber to the Home) and long-distance backhaul systems. Features FRP/aramid strength.

    [PDF Version]
  • How to straighten a bent pigtail cable

    How to straighten a bent pigtail cable

    The most common technique for removing a kink involves manual untwisting combined with steady, gentle tension. This process requires identifying the direction of the original twist that caused the kink and then carefully reverse-twisting the cable to counteract the material's. A kink in a cable is a sharp, localized bend or twist that permanently deforms the material's intended geometric structure. To make the tangled, twisted cables or cord straight again you can use a few method. Within just a few minutes, you can make the wire's bends and kinks disappear! Wrap one end of the wire around a screwdriver shaft. I use several useful tricks in doing so.


  • How much data can an 8-core optical fiber cable transmit

    How much data can an 8-core optical fiber cable transmit

    This architecture can handle 40Gbps transmission rates in a single fiber optic cable, making it great for environments with a lot of data and high bandwidth needs. Fiber-optic cable bandwidth determines how much data your network can handle, directly impacting business operations from video conferencing to file transfers. With modern fiber systems achieving up to 1. Understanding this key aspect is crucial for making the right choice. The primary types of multimode fiber, OM1, OM2, OM3, OM4 and OM5, differ in terms of standardization and. Imm (main cord) Material Stainless Steel Color Silvery White UL94 V-0 (*Burning stops within 10 seconds on a veritcal specimen, no drips of flaming particles.


  • How many grounding points are needed for fiber optic cables

    How many grounding points are needed for fiber optic cables

    Conductive fiber optic cable per NEC 770. 100 must be grounded through a bonding or grounding electrode conductor. listed 6 AWG copper strand and. Fiber optic cable transmits data as light through glass or plastic strands, which means the fiber core itself carries no electrical current and requires no grounding. The critical distinction lies in. This Applications Engineering Note (AE Note) discusses conventional bonding and grounding practices for conductive fiber optic cable and hardware installations within the scope of the National Electrical Code (NEC). The isolating of exposed guys includes both overhead and anchor guys. 93 Grounding or Interruption of Non–Current-Carrying Metallic Members of Optical Fiber Cables.


Need Product Pricing?

Contact us for competitive quotes on any of our fiber optic and telecom products

Get a Quote