+27 21 852 4719 [email protected] Mon-Fri 8:00-17:30 (SAST)
How To Choose An It Rack

How To Choose An It Rack

Browse technical resources about OM5/OS2 fiber, FC/ST connectors, distribution boxes, circulators, QSFP28, PDU, FTTR, rail transit and communication cabling.

  • How to route too many cables in an outdoor server rack

    How to route too many cables in an outdoor server rack

    A common approach is to run cables across the rear of the rack before routing them up or down through cable managers, which keeps them grouped by function and reduces tangles. Take note of your servers, switches, and other devices, power distribution units (PDUs) locations, and available rack space to plan clean cable paths that avoid clutter, maintain airflow, and simplify maintenance. Disorganized cables can lead to network downtime, overheating, and even safety hazards like tripping or fire risks. Done without regard for planning and deployment factors, however, a spaghetti tangled mess of wires can introduce. In server rooms and data centers, multiple power and data cables connect servers, switches, and networking equipment within rack systems.


  • How to Choose a Central Asia Optical Power Meter

    How to Choose a Central Asia Optical Power Meter

    When selecting the best optical fiber power meter for your needs, prioritize accuracy, wavelength range compatibility (e., 850nm, 1310nm, 1550nm), and ease of use. This guide is written to equip readers with the power meter selection know-how necessary for making sound decisions regarding purchasing these devices. For most field technicians and network installers, a handheld dual-wavelength model with auto-ranging capability and LCD backlighting. Our 1936-R/2936-R series boasts state-of-the-art analog boards with a whopping 250 kHz sampling rate and femtowatt level resolution, easily dwarfing competition. Our optical power meters feature built-in calibration factors. Santec offers a comprehensive range of Optical Power Meters designed to meet diverse testing requirements in fiber optic applications. Asia-Pacific Optical Power Meter Market, By Type (Thermal Detectors and Photo Detectors), Instrument/Product Type (Benchtop Meter, Portable Meter, Virtual Meter, Optical Wavelength, Hand-Held Meter, and Others), Detector Type (InGaAs (Indium Gallium Arsenide), Germanium, Silicon, and Others), Power.

    [PDF Version]
  • How much does it cost to upgrade a home network server rack

    How much does it cost to upgrade a home network server rack

    In the US, a fully equipped rack can cost anywhere between $15,000 and $50,000 or more, depending on your requirements. This includes multiple servers, which may cost $1,000 to $5,000 each, along with storage systems and networking equipment like switches and routers. The main cost drivers include cabinet height (in rack units), construction (steel, powder coating), security features, and any power distribution or cable management accessories. Entry-level racks, such as small wall-mounted units, typically range from $200 to $500. Typical price ranges reflect whether the server is for media, light backups, or enterprise-grade uptime. When considering a network upgrade, it's important to look beyond just the price tag of new hardware. Size of the Data Center The scale of the data center plays a large.


  • How is the height of a network server rack indicated

    How is the height of a network server rack indicated

    Server racks are typically designated by height, measured in “rack units” or “Us. 45mm), so a 42U rack is 73. 90mm) of. Most professional server racks follow the EIA-310 standard, which defines: These standards make it possible for any 19-inch compatible device to fit securely within the rack, regardless of brand. Rack Units Explained: The Foundation of Server Rack Sizes The fundamental measurement of rack height is. The three primary dimensions to consider are rack height (measured in rack units or U), rack width (most commonly the industry-standard 19-inch format), and rack depth (typically ranging from 24 inches to 48 inches). Each of these factors influences equipment fit, airflow management, cable routing. Common server rack sizes are 19‑inch width, heights like 42U or 48U, and depths from ~24″ to 48″. Most IT environments default to 42U, 19-inch width, and 1000–1200 mm depth unless space constraints or special equipment dictate. A “Rack Unit” (U) is a standard height measure for mounting equipment in a server rack. This article explains definition, planning, installation tips, and trends.

    [PDF Version]
  • How to choose the size of a three-box distribution box

    How to choose the size of a three-box distribution box

    Pick the right size distribution box to keep things safe. This stops too much power and keeps wires from getting too hot. It also lets you add more stuff later if needed. They help you plan what. How to choose a distribution box of the right size for a project based on load current? Get it right the first time with this comprehensive guide If you're like most electrical professionals, picking the right distribution box for your project can feel like navigating a maze. They are able to guarantee adherence to all pertinent safety regulations and carry out precise load calculations.


  • How to Choose the Width of a Network Cabinet

    How to Choose the Width of a Network Cabinet

    Depth: Common cabinet depths are 600mm, 800mm, and 1000mm. Wider cabinets make cable management easier and provide more side space for accessories. In this guide, we'll walk you through everything you need to know about home networking cabinet sizes, from basic measurements to advanced selection strategies. A properly sized cabinet ensures that your equipment is well organized, cooled effectively, and easy to maintain — all of which contribute to. Selecting the right network cabinet is crucial for the safety and longevity of your network equipment. What is a Network Cabinet? A network cabinet houses and organizes. In this guide, we'll explain what the different sizes mean and help you choose the right one for your space and gear. Rack height is measured in rack units (U) — 1U = 1. Common sizes: 42U, 48U, and compact options like 22U–27U. Standard width is 19 inches (EIA-310 compliant), while outer.

    [PDF Version]
  • How to tell if a network server rack is good or not

    How to tell if a network server rack is good or not

    Selecting the right rack requires evaluating its height (U), depth, width, weight capacity, airflow design, power integration (PDU/UPS/ATS), cable management strategy, and environmental monitoring options. A data center server rack is the physical foundation of modern IT infrastructure, enabling the organized installation of servers, switches, PDUs, UPS systems, and structured cabling. There are three primary rack types - open-frame racks, enclosed cabinets, and wall-mount racks, each suited for. Server racks are open frames or cabinets designed for mounting, organizing and securing EIA-standard 19-inch width rack-mount IT and A/V equipment such as servers, routers, hubs, switches and audio/video components, regardless of the manufacturer. They also provide cable management and enable. This guide covers every aspect—from a comprehensive introduction and detailed technical parameters (with specific numbers for plate thickness, width, and more), to the common types of racks and their pros, cons, and applications. However, selecting a rack can be overwhelming if you're not sure where to start.

    [PDF Version]
  • How to choose the size of a five-room electrical distribution box

    How to choose the size of a five-room electrical distribution box

    The following example will show you how to find the right size of single phase 230V AC consumer unit or garage unit and associated MCB/MCCB to handle the residential load.The common voltage levels for residential applications in the USA are 120V and 240V single-phase. Three wires (identified as Hot 1 with black color, Hot 2 with red color, and Neutral with white color) from the secondary side of the split-phase transformer enter the meter box and the main service panel (main switch breaker). In this case, the availa. In the following example, we will show you how to calculate the right size of three phase 400V distribution board which is mostly applicable in countries following the IEC rules e.g. UK, EU and former British colonies. Good to Know: It is.


  • How do I unplug the cable from the fiber optic panel

    How do I unplug the cable from the fiber optic panel

    Grasp the connector body (not the cable!) of the fiber optic or copper cable. Never pull the cable itself to remove the connector. As an experienced technology writer who has covered broadband advancements for over a decade, I aim to provide readers with trustworthy instructions endorsed by industry experts. Not my pic, but didn't feel like moving the.


  • How to bend a double-layer cable tray

    How to bend a double-layer cable tray

    You can buy a manufactured 90 degree bend or make one on a cable tray bending machine but in this video I show you how to make one using a metal bar. more. This publication is intended as a practical guide for the proper and safe* installation of cable ladder systems, cable tray systems, channel support systems and associated supports. Cable ladder systems and cable tray systems shall be manufactured in accordance with BS EN 61537, channel support. en completely installed, without damage either to conductors or structural system use maintain spacing or to keep cables in place when the tray is ect the minimum bend ra-dius for cables as they exit the bottom of the cable tray. Since the jaws of the bolt cutter drags a layer of zinc across the cut end and forms a protective layer. The first step in preparing the. The B-Line series Cable Tray Manual was produced by our technical staff.

    [PDF Version]

Need Product Pricing?

Contact us for competitive quotes on any of our fiber optic and telecom products