+27 21 852 4719 [email protected] Mon-Fri 8:00-17:30 (SAST)
How To Configure Wireless Access Points

How To Configure Wireless Access Points

Browse technical resources about OM5/OS2 fiber, FC/ST connectors, distribution boxes, circulators, QSFP28, PDU, FTTR, rail transit and communication cabling.

  • How to configure an access switch to connect to a router

    How to configure an access switch to connect to a router

    To connect a router to a switch, simply plug an Ethernet cable into one of the router's LAN ports and connect the other end to any port on the switch. This creates a seamless network where multiple devices can share the internet connection and communicate efficiently. Knowing how to connect switch to router is quite essential to enter the ethernet network. In this blog, we'll provide a step-by-step guide to help you achieve it. For more guidance on expanding your wired network, continue reading this guide. By following a few simple steps, you can maximize the efficiency of your home or office network and ensure seamless internet access for all your devices.


    FAQs about How to configure an access switch to connect to a router

    How do you configure router settings?

    Sometimes, the network settings on your PC aren't enough for your needs. If you need access to remote management or your IP address, you can log in...

    Which cable is used to connect a router to the switch?

    You use a gigabit ethernet cable, sometimes called a crossover cable, to connect a router to a switch. Since crossover cables are pretty short, you...

    Is ethernet really faster than Wi-Fi?

    Having a wired connection gives you access to gigabit speeds of up to 1 gigabit per second (Gbps) or 1000 megabits per second (Mbps). While Wi-Fi f...

  • How to prevent loops on access switches

    How to prevent loops on access switches

    To stop a network loop, enable the Spanning Tree Protocol (STP) or Rapid Spanning Tree Protocol (RSTP) on your switches to ensure a loop-free topology. Utilize switch features like BPDU Guard, Root Guard, and Loop Guard to prevent loops. Looking for some advice on what would be the best approach to prevent physical loops at the access layer. Our existing design is quite simple, it consists of several switches acting as layer 2 (around 6-7) and all of them are connected to a switch through single interface trunk ports. MSTP also configured, all vlans are in one instance where core is the root bridge. What Causes a Network Loop? A network loop can occur due to: ✅ Redundant Cable Connections – Multiple physical links between switches.


  • How to select switch port access

    How to select switch port access

    An access port connects an end device like a PC or printer to one VLAN on a Cisco switch. Then you assign a VLAN ID with "switchport access vlan" plus the number. Trunk ports allow traffic for multiple VLANs, while access ports handle. A VLAN is a switched network that is logically segmented by function, project team, or application, without regard to the physical locations of the users. VLANs have the same attributes as physical LANs, but you can group end stations even if they are not physically located on the same LAN segment.


  • How many cores does a fiber optic access switch need

    How many cores does a fiber optic access switch need

    A simple rule is that each device needs two cores—one for sending and one for receiving data. (actually use a four core optical cable) This is because apart from one-core optical fiber, there are basically no optical cables with an odd number of cores, such as three-core, five-core, etc. The total number of cores for a 1pc fiber patch cable is calculated as the number of. Common fiber cores include 1 core, 2 cores, 6 cores, 8 cores, etc. When selecting fiber, the first step is to determine single mode or multimode, and. Fiber optic cables consist of multiple thin strands of glass or plastic, known as “cores. ” These cores carry the data signals via light.


  • How to configure interconnection between core switches

    How to configure interconnection between core switches

    To establish a VSX relationship between the core switches, create a link aggregation (LAG) interface for assignment as the VSX data plane's inter-switch link (ISL). The LAG can be defined at the Central UI group level when using the same ports for the VSX ISL on both core. Therefore, you are advised to configure corresponding VPN instances on the core switch to isolate traffic and send the traffic to the corresponding ISPs. It is a 12-bit identity used to create multiple broadcast domains in a switch. VLAN ranges from 0 to 4095 (VLAN 0 and VLAN 4095 are reserved and not used). This Switch Port mode is configured by the admin. The slot is used to install various function modules and interface modules.


  • How much does it cost to fuse 12 core optical cables at once

    How much does it cost to fuse 12 core optical cables at once

    For most commercial projects, expect to pay $50–$150 per fusion splice point - but that number can swing in either direction based on the factors below. Fiber optic splicing costs vary widely depending on project size, location, fiber type, and site conditions. Understanding these factors can help businesses and individuals budget effectively for fiber optic. This price is fixed unit cost. Splicing Services – Enclosure Prep. 00 per Enclosure Point Travel/Mobilization – Travel/Mobilization will not be charged if the labor for each trip/phase exceeds the minimum labor work as indicated below. If the minimum labor work figured is not met, then. I usually bill T&M, but it works out to about $175-250 for setup/teardown per site and $4-7 per fiber for prep in a new tray in an existing case and splicing depending on if it's flooded or dry cable. Add another $50-75 to prep a new case endspan or $100-150 for a new case midspan with overcut on. Buying fiber optic installation services involves several cost components, with total price influenced by length, location, and access.

    [PDF Version]
  • How to peel the coating off pigtail fiber

    How to peel the coating off pigtail fiber

    Remove the outer coating carefully to expose the fiber. Use alcohol wipes to remove dust and debris. Make a precise cut for optimal splicing. Use an OTDR or power meter to ensure. The most efficient way to terminate a fiber run is by using a pigtail. A fiber pigtail is a short length of optical fiber that comes with a high-quality, factory-polished connector already installed on one end, leaving a length of exposed glass on the other. Instead of building a connector from. Executive Summary: A fiber optic pigtail is one of the most commonly specified yet least understood components in structured cabling. Get the wrong connector type, the wrong polish, or skip proper fusion splicing technique—and you're looking at elevated signal loss, increased back reflection, and a. Installing fiber optic pigtails correctly is essential for ensuring low signal loss and long-term reliability.

    [PDF Version]
  • How to connect the main power line of the fire protection distribution box

    How to connect the main power line of the fire protection distribution box

    Connect the phase and neutral wires from the input power supply to the input of the Main MCB. Follow this guide for a clear and safe connection process: Before starting, always ensure the main power is turned off to avoid electrical shock. ‌Wiring Direction‌: Wiring between the main circuit breaker and each branch circuit breaker in the box generally. A distribution board or distribution box is where the main power supply is distributed to multiple loads. And all the switching and protective devices are installed in the distribution box. A cable distribution box is an electrical device used to collect, distribute, and protect electrical power.


  • How much loss per kilometer of optical cable

    How much loss per kilometer of optical cable

    Single-mode fiber typically shows its lowest loss near 1550 nm, often around 0. Multimode fiber can be higher and depends strongly on grade and wavelength. Field measurements may be. ANSI/TIA/EIA-568-B. ) (This does not include the connectors that plug into the end equipment. This value should be determined by the system designer. Attenuation Coefficient (dB/km): This value represents the inherent signal loss per kilometer of. Manufacturers provide a fiber loss factor in dB per kilometer. Example Calculator #1: The following formula is used for Calculator #1: This calculator calculates the fiber output power based on the fiber cable loss (dB/Km), length of the cable.


  • How many meters is a long-span cable tray

    How many meters is a long-span cable tray

    The straight length of an ordinary cable tray is generally 2 meters. However, other common lengths include 3 meters, 4 meters, and 6 meters. Cable trays that extend beyond 2 meters, such as those that are 8 meters or 9 meters in length, are classified as large-span cable trays. In practice, cable tray dimensions are a system of interrelated measurements —width, depth, length, and material thickness—that directly affect cable fill compliance, heat dissipation, structural loading, and long-term expandability. Suitable for high-bay warehouses, stadiums, bridges, and industrial facilities with limited support points, it efficiently supports heavy cable loads (power cables. Compared with the common cable tray, the characteristics of the long-span cable tray is that it has a larger single length and installation length. The long-span cable tray. For cable tray applications lacking sufficient space for the number of supports required for standard-length sections, choose T&B Cable Tray long-span AH1-8 series aluminum cable tray in 40-foot (12.

    [PDF Version]

Need Product Pricing?

Contact us for competitive quotes on any of our fiber optic and telecom products

Get a Quote